Report: The Sink Drain as a Source of Hospital-Acquired Infections

Healthcare Poland report · HCPL-2026-RAP-001 · public edition · November 2026

Sink drains in Polish hospitals should be brought into the infection prevention system on the same terms as surfaces, equipment and staff hands.

droplet splash: approx. 1 mREPORT · HCPL-2026-RAP-001 · PUBLIC EDITIONThe sink drainas a source ofhospital infectionsA reservoir of antibiotic-resistant bacteriathat Polish surveillance does not cover.

The Healthcare Poland Foundation has published a collective study, led by Michał P. Dybowski, on an infection reservoir that the Polish surveillance system does not yet see: the traps and waste pipes of hospital sinks. The report runs to 78 pages. It organises twenty years of literature, sets it against data from ECDC and the Polish State Sanitary Inspectorate, describes the legal framework binding on a hospital director, and closes with fifteen graded recommendations and a commentary for health policy.

The full report is available in Polish. The order form is in Polish: enter your e-mail address, name, organisation and its REGON number if you have one. Wersja polska tej strony: Raport: Odpływ umywalki jako źródło zakażeń szpitalnych.

The thesis and its grounds

Prevention of hospital-acquired infections in Poland rests on three pillars: hand hygiene, decontamination of surfaces and equipment, and isolation of carriers. The report argues that this arrangement has a gap. The trap and the waste pipe are a persistent reservoir of multidrug-resistant Gram-negative bacilli, including carbapenemase-producing Enterobacterales (CPE). The reservoir re-establishes itself after every disinfection, and bacteria reach the patient through droplets splashed within about one metre. Since the mechanism is described and the duty to assess risk lies with the hospital director, leaving drains out is not neutral: it is a decision to leave a known source uncontrolled.

Scale: the 2030 target is receding

The Council Recommendation of 13 June 2023 (2023/C 220/01) sets Poland the target of reducing the incidence of bloodstream infections with carbapenem-resistant Klebsiella pneumoniae to 1.32 per 100,000 population by 2030, against 1.38 in the 2019 baseline year. According to ECDC, the rate in 2024 was 5.15, which is 273% above the baseline. To meet the target, Poland would have to cut incidence by about three quarters within six years.

SCALE OF THE PROBLEM IN POLANDResistance is rising faster than the 2030 target allows5.15carbapenem-resistantK. pneumoniae bacteraemiasper 100,000 people (2024)+273%increase vs 2019 (1.38);the EU target for 2030is 1.32307hospital outbreaks ofK. pneumoniae in 2025(249 a year earlier)22,077infections with carbapenem-resistant Enterobacteralesreported in 2025CR-Kp bacteraemias per 100,000 population20191.3820245.152030 target1.32The sink drain recolonisesafter every disinfection andremains outside surveillance.Sources: ECDC (EARS-Net, country factsheet Poland), State Sanitary Inspectorate — report for 2025.

Data from the State Sanitary Inspectorate for 2025 confirm the direction: 307 outbreaks caused by K. pneumoniae against 249 a year earlier, 284 of them by carbapenemase-producing strains, and 22,077 infections with carbapenem-resistant Enterobacterales. The national report does not address drains: the reservoir is not tested, recorded or reported. The Polish resistance profile is dominated by NDM metallo-β-lactamase, against which the newest antibiotic–inhibitor combinations do not work. With such a profile, preventing acquisition is a stronger lever than treatment.

Mechanism: from the trap to the patient

The report traces the route step by step. Bacteria colonise the trap and form a biofilm. The biofilm grows up the waste pipe towards the sink strainer. The water stream hitting the drain disperses droplets into the surroundings. Droplets land on the bed, equipment, medicines being prepared and hands, and from there reach the patient. Dozens of outbreaks have been described in which isolates from drains were genetically identical to isolates from patients; in one large centre a contaminated sink was the suspected source for 40% of patients who acquired CPE in hospital.

MECHANISMFrom the trap to the patient: four steps1Biofilm in the trapResistant bacteria colonise the trap; disinfection does not remove them for good.2Growth towards the strainerThe biofilm grows up the pipe towards the sink strainer.3SplashThe water stream disperses droplets within about one metre.4PatientDroplets land on the bed, equipment, medicines and hands, and reach the patient.Most at risk: haematology, oncology, intensive care, transplant, neonatal and burns units.

Those most at risk are haematology and oncology patients, and patients in intensive care, transplant, neonatal and burns units. In haematology patients with bloodstream infection caused by carbapenem-resistant K. pneumoniae, 21-day mortality exceeded 50%.

What the evidence says, and what it does not

The study separates what is established from what is promising. Each study is graded separately for its design and for its form of publication.

  • Design changes give the most durable effects: the position of the drain, the distance between sink and patient, fewer sinks. The “water-free” model of care has some of the best documented results in Europe.
  • Chemical and thermal disinfection works temporarily. In a randomised trial it added no benefit beyond replacing the trap.
  • Engineering solutions at trap level are promising, but most studies come from a single centre with a before–after design, and a study on a haematology ward found no effect on patient colonisation.
  • No single study proves causation in every dimension, and the share of this route in the overall number of infections remains unknown. The report says so plainly.

The study is technology-neutral: it assesses principles of operation and the quality of evidence, and names no products or suppliers. The Healthcare Poland Foundation does not sell or distribute devices.

Law: the duty already exists, the tools need review

The Polish Act of 5 December 2008 on preventing and combating infections and infectious diseases in humans (consolidated text: Journal of Laws 2025, item 1675, as amended) requires the head of a healthcare entity to assess infection risk and to run internal control. Drains fall within that duty without any change in the law. At the same time, § 24 of the Regulation of the Minister of Health of 26 March 2019 on the detailed requirements for the premises and equipment of an entity performing medical activity (consolidated text: Journal of Laws 2022, item 402) as a rule requires a sink in a patient room. The report recommends reviewing this provision for high-risk wards, so that a hospital can choose the layout that is safer for the patient.

Recommendation: order and measurement first

The report sets out fifteen recommendations for hospitals, each with its strength and basis. They share one axis: action begins with inventory and measurement, and technology comes in only when measurement has shown a reservoir and basic measures have not reduced acquisitions.

RECOMMENDATIONOrder and measurement first, technology in phase 3PHASE 0Order0–3 monthsteam, sink inventory,rules of usePHASE 1Measure3–6 monthsdrain samples,mapping acquisitionsPHASE 2Basicsdecontamination,trap replacementPHASE 3Pilot≥ 12 monthscomparison group,stopping criterionPHASE 4Scale-upfurther wards,upkeep, oversightDecision gates are settled by data: if drains are not a reservoir — routine surveillance;if the pilot misses the criterion set in the protocol — do not deploy, and publish the result.Implementation pathway: chapter 12 and annex C of report HCPL-2026-RAP-001.
  1. Include sinks and drains in the infection risk assessment that the hospital director carries out under the Act.
  2. Within 6 months, inventory water points on the highest-risk wards and assign each a risk category.
  3. Adopt the rule that a hand-hygiene sink is used only for washing hands, and that the zone within 1 m of it is kept free of medicines and equipment.
  4. In every CPE outbreak, sample the drains and type the isolates together with isolates from patients.
  5. In every refurbishment and new build, design sinks so that the stream does not hit the drain and the drain is fast and accessible for servicing.
  6. Introduce trap-level technologies first as a pilot with measurement and a failure criterion set before the start.
  7. At system level: review § 24 of the Regulation for high-risk wards, and validate solutions in Polish hospitals in a multi-centre study with a common protocol and analysis independent of suppliers.

What result is within reach

The scenario model in the report sets the order of magnitude. In the base scenario, drain control on anaesthesiology and intensive care units would avoid in Poland about 160 bloodstream infections with carbapenem-resistant K. pneumoniae, about 40 deaths and about PLN 5.2 million in hospitalisation costs a year. That is about 11% of the gap between Poland and the 2030 target. The model does not replace measurement: it sets a result that a pilot is to confirm or refute. Drains are therefore one element of the infection prevention package, not a substitute for it.

Who the report is for

  • Hospital directors — the scope of the duty, sink risk categories, a five-phase implementation pathway.
  • Infection control teams and epidemiologists — a sink inventory card, a drain sampling protocol, indicators and control variables.
  • Technical and investment departments — design requirements for hand-hygiene stations and the regulatory status of devices fitted into the installation.
  • Administration and oversight bodies — the reporting gap, a proposed surveillance indicator and the direction of the regulatory review.

The full report is available in Polish. The order form is in Polish: enter your e-mail address, name, organisation and its REGON number if you have one. Wersja polska tej strony: Raport: Odpływ umywalki jako źródło zakażeń szpitalnych.

Invitation to hospitals

Hospitals interested in taking part in a multi-centre pilot with measurement, run under the protocol in annex C of the report, are invited to contact the Healthcare Poland Foundation: global@healthcarepoland.pl, tel. +48 787 000 827.

Authors and funding

A collective study by Healthcare Poland, led by Michał P. Dybowski. Quality: Piotr Welenc · compliance: Ewelina Bogiel · legal: Robert Kroplewski · research plan: Paweł Gołda · data and analysis: Piotr Senkus · problem definition: Marcin Karolewski · commentary and review: Jarosław Fedorowski.

The study was financed solely from the Healthcare Poland Foundation’s own funds. No external entity funded its preparation.

How to cite: Healthcare Poland (2026). Odpływ umywalki jako źródło zakażeń szpitalnych [The sink drain as a source of hospital-acquired infections]. Collective study led by Michał P. Dybowski. HCPL-2026-RAP-001, public edition. Warsaw: Healthcare Poland Foundation.
Contact: global@healthcarepoland.pl · +48 787 000 827